Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorKarataş, F.
dc.contributor.authorKoyuncu, I.
dc.contributor.authorTuna, Murat
dc.contributor.authorAlçın, M.
dc.contributor.authorAvcıoğlu, E.
dc.contributor.authorAkgül, A.
dc.date.accessioned2021-12-12T17:03:24Z
dc.date.available2021-12-12T17:03:24Z
dc.date.issued2021
dc.identifier.issn1951-6355
dc.identifier.issn1951-6401
dc.identifier.urihttps://doi.org/10.1140/epjs/s11734-021-00334-3
dc.identifier.urihttps://hdl.handle.net/20.500.11857/3669
dc.description.abstractIn this study, eight arrhythmic ECG signals from vital signals [sinus tachycardia, supraventricular tachycardia, premature ventricular complex (PVC), atrial fibrillation, AV block: 3rd degree, ventricular fibrillation, sinus bradycardia, first-degree AV block] were designed mathematically, and then modelled on FPGA by VHDL and Xilinx-Vivado software. The mathematical extrapolation of the signals was created in accordance with the literature and after examining the time and amplitude values of many ECG signals from the Physiobank ATM section of the MIT-BIH (Massachusetts Institute of Technology-Beth Israel Hospital) arrhythmia database. These signals were synthesized for the Zynq-7000 XC7Z020 FPGA chip for using in biomedical calibration applications and ECG simulators. The ECG signals were modelled with a 14-bit AD9767 DAC module that worked in coherence with this development board, and observed in real-time by 4 channel oscilloscope. Matlab-based ECG signals were taken as reference and compared with the results obtained from the FPGA-based ECG signals design. The FPGA chip resource consumption values obtained after the place-route process, the test results obtained from the design, the MSE (mean squared error) values of the designed signals, the operating frequencies of the system and each signal have been presented. The maximum operating speed of this system is 651.827 MHz. In this study, it has been shown that FPGA-based ECG signal generation system can be implemented on FPGA chips, and the designed system can be safely used in ECG simulators.en_US
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK)Turkiye Bilimsel ve Teknolojik Arastirma Kurumu (TUBITAK) [119E659]en_US
dc.description.sponsorshipThis study is sponsored by the Scientific and Technological Research Council of Turkey (TUBITAK) with project number 119E659.en_US
dc.language.isoengen_US
dc.publisherSpringer Heidelbergen_US
dc.relation.ispartofEuropean Physical Journal-Special Topicsen_US
dc.identifier.doi10.1140/epjs/s11734-021-00334-3
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectReal-Timeen_US
dc.subjectSystemen_US
dc.subjectClassifieren_US
dc.subjectGeneratoren_US
dc.titleDesign and implementation of arrhythmic ECG signals for biomedical engineering applications on FPGAen_US
dc.typearticle
dc.departmentFakülteler, Mühendislik Fakültesi, Elektrik-Elektronik Mühendisliği Bölümü
dc.departmentMeslek Yüksekokulları, Teknik Bilimler Meslek Yüksekokulu, Elektrik ve Enerji Bölümü
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid57352413000
dc.authorscopusid53984519400
dc.authorscopusid55566680600
dc.authorscopusid55807412400
dc.authorscopusid57352566600
dc.authorscopusid43261096500
dc.identifier.wosWOS:000722547600002en_US
dc.identifier.scopus2-s2.0-85119841737en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster