Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorDursun, Bahtiyar
dc.date.accessioned2021-12-12T17:02:05Z
dc.date.available2021-12-12T17:02:05Z
dc.date.issued2012
dc.identifier.issn1364-0321
dc.identifier.urihttps://doi.org/10.1016/j.rser.2012.07.017
dc.identifier.urihttps://hdl.handle.net/20.500.11857/3373
dc.description.abstractThis study is to search for possibilities of supplying the load demand of Kavakli campus of Kirklareli University with solar energy and the fuel cell power generating system (electrolyzer/hydrogen tank/fuel cell) by using the HOMER software due to the fact that hybrid power systems with renewables can significantly reduce emissions which are caused by utilization of non-renewable power sources. In this study, various hybrid systems will be examined and compared among themselves considering cost of energy (COE), renewable fraction, total net present cost (NPC) and hydrogen production. Additionally, this study will seek whether a fuel cell can be integrated into the hybrid systems. According to the study results, the grid connected systems appear cost-effective as expected. Although the grid-connected photovoltaic (PV) hybrid system has the lowest COE and NPC, the grid-connected PV/fuel cell hybrid system with COE, 0.294$/kWh has a slightly higher cost than the optimum one. It is strongly believed that this system may be chosen because it is a cleaner system and its emissions are fairly low. (C) 2012 Elsevier Ltd. All rights reserved.en_US
dc.description.sponsorshipKirklareli UniversityKirklareli Universityen_US
dc.description.sponsorshipI am fairly thankful to the TEIAS and Turkish State Meteorological Service for providing the load data and solar data of the Kavakli campus of Kirklareli University, respectively. Also, I would like to thank Kirklareli University for supporting this study.en_US
dc.language.isoengen_US
dc.publisherPergamon-Elsevier Science Ltden_US
dc.relation.ispartofRenewable & Sustainable Energy Reviewsen_US
dc.identifier.doi10.1016/j.rser.2012.07.017
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPV arrayen_US
dc.subjectHybrid power systemsen_US
dc.subjectFuel cellen_US
dc.subjectRenewable energyen_US
dc.subjectOptimizationen_US
dc.titleDetermination of the optimum hybrid renewable power generating systems for Kavakli campus of Kirklareli University, Turkeyen_US
dc.typereview
dc.authoridDursun, Bahtiyar/0000-0002-6036-7408
dc.authoridDursun, Bahtiyar/0000-0003-2213-3317
dc.departmentFakülteler, Mühendislik Fakültesi, Elektrik-Elektronik Mühendisliği Bölümü
dc.identifier.volume16en_US
dc.identifier.startpage6183en_US
dc.identifier.issue8en_US
dc.identifier.endpage6190en_US
dc.relation.publicationcategoryDiğeren_US
dc.authorscopusid23986971300
dc.identifier.wosWOS:000311184800059en_US
dc.identifier.scopus2-s2.0-84865657444en_US
dc.institutionauthorDursun, Bahtiyar
dc.authorwosidDursun, Bahtiyar/N-9077-2019


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster