dc.contributor.author | Dönmez, Soner | |
dc.contributor.author | Arslan, Fatma | |
dc.contributor.author | Sarı, Nursen | |
dc.contributor.author | Yetim, Nurdan Kurnaz | |
dc.contributor.author | Arslan, Halit | |
dc.date.accessioned | 2021-12-12T17:00:44Z | |
dc.date.available | 2021-12-12T17:00:44Z | |
dc.date.issued | 2014 | |
dc.identifier.issn | 0956-5663 | |
dc.identifier.issn | 1873-4235 | |
dc.identifier.uri | https://doi.org/10.1016/j.bios.2013.10.059 | |
dc.identifier.uri | https://hdl.handle.net/20.500.11857/2869 | |
dc.description.abstract | In this study, a novel carbon paste electrode that is sensitive to glucose was prepared using the nanoparticles modified (4-Formyl-3-methoxyphenoxymethyl) with polystyren (FMPS) with L-Glycine-Pt (IV) complexes. Polymeric nanoparticles having Pt(IV) ion were prepared from (4-Formyl-3-methoxyphenoxymethyl) polystyren, glycine and PtCl4 by template method. Glucose oxidase enzyme was immobilized to a modified carbon paste electrode (MCPE) by cross-linking with glutaraldehyde. Determination of glucose was carried out by oxidation of enzymatically produced H2O2 at 0.5 V vs. Ag/AgCl. Effects of pH and temperature were investigated, and optimum parameters were found to be 8.0 and 55 degrees C, respectively. Linear working range of the electrode was 5.0 x 10(-6)-1.0 x 10(-3) M, R-2=0.997. Storage stability and operational stability of the enzyme electrode were also studied. Glucose biosensor gave perfect reproducible results after 10 measurements with 2.3% relative standard deviation. Also, it had good storage stability (gave 53.57% of the initial amperometric response at the end of 33th day). (C) 2013 Elsevier B.V. All rights reserved. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Elsevier Advanced Technology | en_US |
dc.relation.ispartof | Biosensors & Bioelectronics | en_US |
dc.identifier.doi | 10.1016/j.bios.2013.10.059 | |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Biosensor | en_US |
dc.subject | Carbon paste | en_US |
dc.subject | Glucose oxidase | en_US |
dc.subject | Nanoparticule | en_US |
dc.subject | Pt(IV) complexes | en_US |
dc.title | Preparation of carbon paste electrodes including poly(styrene) attached glycine-Pt(IV) for amperometric detection of glucose | en_US |
dc.type | article | |
dc.authorid | Donmez, Soner/0000-0003-0328-6481 | |
dc.authorid | Donmez, Soner/0000-0003-0328-6481 | |
dc.department | Fakülteler, Fen-Edebiyat Fakültesi, Kimya Bölümü | |
dc.identifier.volume | 54 | en_US |
dc.identifier.startpage | 146 | en_US |
dc.identifier.endpage | 150 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.authorscopusid | 26534263900 | |
dc.authorscopusid | 7003890797 | |
dc.authorscopusid | 7003536574 | |
dc.authorscopusid | 55934629400 | |
dc.authorscopusid | 36766563400 | |
dc.identifier.wos | WOS:000333071500022 | en_US |
dc.identifier.scopus | 2-s2.0-84888068652 | en_US |
dc.identifier.pmid | PubMed: 24269757 | en_US |
dc.authorwosid | Donmez, Soner/C-3562-2014 | |
dc.authorwosid | ARSLAN, Fatma/B-7452-2016 | |
dc.authorwosid | ARSLAN, Halit/A-4121-2016 | |
dc.authorwosid | SARI, NURSEN/AAA-8328-2021 | |
dc.authorwosid | Donmez, Soner/AAH-4908-2020 | |