Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorDönmez, Soner
dc.contributor.authorArslan, Fatma
dc.contributor.authorSarı, Nursen
dc.contributor.authorYetim, Nurdan Kurnaz
dc.contributor.authorArslan, Halit
dc.date.accessioned2021-12-12T17:00:44Z
dc.date.available2021-12-12T17:00:44Z
dc.date.issued2014
dc.identifier.issn0956-5663
dc.identifier.issn1873-4235
dc.identifier.urihttps://doi.org/10.1016/j.bios.2013.10.059
dc.identifier.urihttps://hdl.handle.net/20.500.11857/2869
dc.description.abstractIn this study, a novel carbon paste electrode that is sensitive to glucose was prepared using the nanoparticles modified (4-Formyl-3-methoxyphenoxymethyl) with polystyren (FMPS) with L-Glycine-Pt (IV) complexes. Polymeric nanoparticles having Pt(IV) ion were prepared from (4-Formyl-3-methoxyphenoxymethyl) polystyren, glycine and PtCl4 by template method. Glucose oxidase enzyme was immobilized to a modified carbon paste electrode (MCPE) by cross-linking with glutaraldehyde. Determination of glucose was carried out by oxidation of enzymatically produced H2O2 at 0.5 V vs. Ag/AgCl. Effects of pH and temperature were investigated, and optimum parameters were found to be 8.0 and 55 degrees C, respectively. Linear working range of the electrode was 5.0 x 10(-6)-1.0 x 10(-3) M, R-2=0.997. Storage stability and operational stability of the enzyme electrode were also studied. Glucose biosensor gave perfect reproducible results after 10 measurements with 2.3% relative standard deviation. Also, it had good storage stability (gave 53.57% of the initial amperometric response at the end of 33th day). (C) 2013 Elsevier B.V. All rights reserved.en_US
dc.language.isoengen_US
dc.publisherElsevier Advanced Technologyen_US
dc.relation.ispartofBiosensors & Bioelectronicsen_US
dc.identifier.doi10.1016/j.bios.2013.10.059
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBiosensoren_US
dc.subjectCarbon pasteen_US
dc.subjectGlucose oxidaseen_US
dc.subjectNanoparticuleen_US
dc.subjectPt(IV) complexesen_US
dc.titlePreparation of carbon paste electrodes including poly(styrene) attached glycine-Pt(IV) for amperometric detection of glucoseen_US
dc.typearticle
dc.authoridDonmez, Soner/0000-0003-0328-6481
dc.authoridDonmez, Soner/0000-0003-0328-6481
dc.departmentFakülteler, Fen-Edebiyat Fakültesi, Kimya Bölümü
dc.identifier.volume54en_US
dc.identifier.startpage146en_US
dc.identifier.endpage150en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid26534263900
dc.authorscopusid7003890797
dc.authorscopusid7003536574
dc.authorscopusid55934629400
dc.authorscopusid36766563400
dc.identifier.wosWOS:000333071500022en_US
dc.identifier.scopus2-s2.0-84888068652en_US
dc.identifier.pmidPubMed: 24269757en_US
dc.authorwosidDonmez, Soner/C-3562-2014
dc.authorwosidARSLAN, Fatma/B-7452-2016
dc.authorwosidARSLAN, Halit/A-4121-2016
dc.authorwosidSARI, NURSEN/AAA-8328-2021
dc.authorwosidDonmez, Soner/AAH-4908-2020


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster