dc.description.abstractWith the impact of global warming, recent years has witnessed a tremendous revival of interest in environmental issues. At the moment, the world's electricity generation mainly depends on the fossil fuels which are eventually going to be run out. On the other hand, fossil fuels have an extremely negative effect on the environment. Therefore, electrical energy savings have become an important factor in the protection of environment. All over the world, lighting of the domestic and commercial buildings as an average consumes about 30% of the electricity produced. One way of the saving electricity in lighting is the utilization of natural daylight. In fact, natural daylight can be a solution for the lighting requirements of the buildings, especially during the daytime. The benefits of using daylight are manifold, such as economical and environmental advantages and the positive effects on human beings. Although there are several methods to use daylight for the illumination purposes, light-pipes are the most simple and versatile of them. In this study, the performance of a light-pipe was investigated in one area, which is a laboratory. The measurements were conducted between February and June. The results of the investigation were presented as the graphs of indoor-outdoor lux versus time. The highest illumination was 449 lux, which was obtained on 12th of May whereas the lowest illumination was 7.51 lux, which was obtained on 26th of February.en_US
dc.description.sponsorshipScientific Research Board of Marmara UniversityMarmara University [BSE-022/020103]en_US
dc.description.sponsorshipThis study is supported by Scientific Research Board of Marmara University with date November 28, 2002 with Project number BSE-022/020103.en_US
dc.language.isoengen_US
dc.publisherSila Scienceen_US
dc.relation.ispartofEnergy Education Science and Technology Part A-Energy Science and Researchen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectDaylighten_US
dc.subjectLight-pipeen_US
dc.subjectEnergy savingsen_US
dc.titleAn investigation into the usability of straight light-pipes in Istanbulen_US
dc.typearticle
dc.authoridEkren, Nazmi/0000-0003-3530-9262
dc.authoridGorgulu, Sertac/0000-0002-8394-5362
dc.departmentFakülteler, Mühendislik Fakültesi, Elektrik-Elektronik Mühendisliği Bölümü
dc.identifier.volume30en_US
dc.identifier.startpage637en_US
dc.identifier.issue1en_US
dc.identifier.endpage644en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid24338101800
dc.authorscopusid55195839800
dc.identifier.wosWOS:000312577400071en_US
dc.identifier.scopus2-s2.0-84872737319en_US
dc.authorwosidEkren, Nazmi/AAA-3546-2019
dc.authorwosidGorgulu, Sertac/ABI-4529-2020


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster