Reduction of cogging torque and improvement of electrical parameters in axial flux permanent magnet (AFPM) synchronous generator with experimental verification
Abstract
This paper presents an axial flux permanent magnet (AFPM) synchronous generator that was manufactured for the reduction of cogging torque by considering the different angles of a rectangle-shaped permanent magnet (RSPM). The placement angle of RSPM was changed from 0 to 28 degrees to obtain total harmonic distortion, line voltage, and cogging torque. A numerical finite element model using Maxwell software was created. The model was validated by the experimental results, with and without a load. The optimum placement angle was obtained at 20 degrees, whose total harmonic distortion (Thd) and cogging torque (Tc) were improved by 41.6% and 71.4%, respectively. © 2020, Electromagnetics Academy. All rights reserved.